Skaitmeninis daugiafunkcinis testeris | išmanus | TRUE RMS (81772) (Kodas: 81772)
SMART UNIVERSAL TRUE RMS METER
81772
Mark
Sthor
Symbol
81772
Series
GRH
Dimensions
123x58x28 mm
Material
ABS
Application
electric
Operating temperature range
0~40 ˚C
Storage temperature
-10 ~ +50 ˚C
Power supply
battery
Battery type
2x1.5V; AAA
Mass
0.075 kg
Display type
LCD
Data Hold
Yes
Circuit continuity test
0-50 Ω
Conduction test
Yes
LED backlight
YES
Flashlight function
NO
Operating relative humidity Rh
<75%
Low battery indicator
Yes
AC voltage measurement
0-600 V a.c.
DC voltage measurement
0-600 V d.c.
Direct current
0-10A
Resistance measurement
0-60 MΩ
Alternating current
0-10A
TRUE RMS
Yes
Automatic measurement range
Yes
Sound signal
Yes
Display range
5999
Automatic shutdown
15 min
Non-contact NCV AC voltage detection
Yes
Smart universal meter by STHOR, symbol 81772, with TRUE RMS function and automatic range for each measurement. The meter will not only automatically select the measurement range, but will also independently determine whether we are currently measuring resistance, circuit continuity, direct or alternating current voltage. This makes the meter very easy to use. In standard meters, before the measurement, we must set the appropriate measurement range and measurement type ourselves. In this meter, after turning it on, you just need to place the measuring probes, e.g. on the battery poles, and then read the result.
Basic measurements
AC voltage measurement: A.C. 0-600V, TRUE RMS
DC voltage measurement: D.C. 0-600V
measurement of alternating current: A.C. 0-10A, TRUE RMS
measurement of direct current intensity: D.C. 0-10A
resistance measurement: 0-60MΩ
circuit continuity test: 0-50Ω
Additional measurements
non-contact detection of alternating voltage: NCV
Measurement accuracy
An example of determining accuracy for measuring AC voltage. Calculations for the measurement result: 235V
measurement accuracy of the 81772 meter for this range is: ±(1.0% + 3), resolution 0.1V
Measurement error calculation formula: (measurement result x 1.0%) + 3 x resolution
calculations: (235 x 1.0%) + 3 x 0.1 = 2.35 + 0.3 = 2.65V
The actual result taking into account the measurement error for the indication 235V = 235 ± 2.65V
result taking into account the measurement error to indicate the DC voltage measurement: 12V = 12 ± 0.09V
result taking into account the measurement error to indicate the measurement of alternating current: 8A = 8 ± 0.164A
A table with the resolution and accuracy for a given measurement can be found in the user manual.
Built-in features
TRUE RMS - a meter with this function calculates the real effective value of alternating voltage and current for both sinusoidal and non-sinusoidal waveforms. The device first measures the actual value of the sine wave at several time intervals → then squares the measurement results → sums them → calculates the average → and finally squares the average result. The measurement result is the real effective value of alternating voltage/current, even for a deformed sine wave or square wave;
NCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in the insulated wire using the NCV sensor on the front of the device;
AUTO - automatic adjustment of the measurement range. When measuring unknown values using a meter with a manual range change using a knob, measurements should be performed sequentially from the largest range to the range giving the most accurate result - otherwise you risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to perform one measurement and the meter will automatically find the optimal range;
SMART - automatic recognition of the measurement type. The meter will recognize itself whether we are measuring direct or alternating current voltage. If no voltage is present, the meter automatically switches to circuit resistance measurement mode;
DATA HOLD - keeping the currently measured value on the display.
Additional information
LCD display, maximum displayed result: 5999
screen backlight
audible signal in the continuity test for resistance below 50Ω
The set includes measurement probes with a length of 12 cm
cable length with probes: 84 cm
wire diameter with insulation: 3.5 mm
ABS plastic housing
automatic shutdown of the meter after 15 minutes of inactivity
low battery indicator
power supply: two 1.5 V (AAA) batteries