Skaitmeninis daugiafunkcinis testeris | TRUE RMS | (9999 AUTO LCD (YT-730893) (Kodas: YT-730893)
Prekių nuotraukos skirtos tik iliustraciniams tikslams, originalių produktų spalvos, užrašai, parametrai, matmenys, dydžiai, funkcijos, ir/ar bet kurios kitos savybės dėl savo vizualinių ypatybių gali atrodyti kitaip negu realybėje, todėl prašome vadovautis prekių savybėmis, kurios nurodytos prekių aprašymuose. Kilus klausimams, visada laukiame Jūsų skambučio telefonu +370 650 61061 arba el. paštu info@drdtools.lt.
Gamintojas: Yato
TRUE RMS DIGITAL METER WITH AUTOMATIC RANGE LCD 19999
Mark
Yato
Symbol
YT-730893
Series
GRE
Dimensions
180x90x45 mm
Material
ABS
Application
electrical
Operating temperature range
0~40 ˚C
Storage temperature
-10 ~ +50 ˚C
Power supply
battery
Battery type
2x1.5V; A.A
Mass
0.319 kg
Display type
LCD
Data Hold
Yes
Circuit continuity test
0-50 Ω
Conduction test
Yes
LED backlight
YES
Flashlight function
NO
Operating relative humidity Rh
<75%
Low battery indicator
Yes
Fuse
F200mAL250V / F20AL250V
AC voltage measurement
0-750 V a.c.
DC voltage measurement
0-999.9 V d.c.
Direct current
0-19.999A
Resistance measurement
0-199.99 MΩ
Diode test
YES
Alternating current
0-19.999A
Capacitance measurement
0-9.999 mF
Frequency measurement
0-9.999MHz
Temperature measurement
-20 ~ +1000 ˚C
Sampling frequency
3 times per second
TRUE RMS
Yes
Automatic measurement range
Yes
Maximum value
Yes
Fill factor measurement
1 ÷ 99%
Minimum value
Yes
Relative value
Yes
Sound signal
Yes
Display range
19999
Automatic shutdown
15 min
Non-contact NCV AC voltage detection
Yes YT-730893 universal meter with TRUE RMS function and automatic range for each measurement. It allows you to perform basic and advanced measurements of electrical quantities. A large multifunctional LCD display, a number of functions that facilitate measurements, speed of work and industrial precision will be appreciated by electronics, electricians and home DIY enthusiasts alike. The housing is equipped with a red rubber holster with dedicated places for measurement probes, thanks to which the meter does not easily slip out of your hands and minimizes the risk of damage during a fall. The test probe cables have silicone, flexible and high-temperature-resistant insulation. BASIC MEASUREMENTS AC voltage measurement: A.C. 0-750V, TRUE RMS
DC voltage measurement: D.C. 0-1000V
measurement of alternating current: A.C. 0-19.999A, TRUE RMS
measurement of direct current intensity: D.C. 0-19,999A
resistance measurement: 0-9,999MΩ
diode test: IF 1.8mA, UR 3.2V
circuit continuity test: 0-50Ω
ADDITIONAL MEASUREMENTS capacitor capacity measurement: 0-9,999mF
frequency measurement: 0-9,999Mhz
fill factor measurement: 1-99%
temperature measurement: -20 to 1000°C
non-contact detection of alternating voltage: NCV
MEASUREMENT ACCURACY An example of determining accuracy for measuring AC voltage. Calculations for the measurement result: 235V measurement accuracy of the YT-730893 meter for this range is: ±(0.3% + 3), resolution 0.1V
Measurement error calculation formula: (measurement result x 0.3%) + 3 x resolution
calculations: (235 x 0.3%) + 3 x 0.1 = 0.705 + 0.3 = 1.005V
The actual result taking into account the measurement error for the indication 235V = 235 ± 1.005V result taking into account the measurement error to indicate the DC voltage measurement: 12V = 12 ± 0.009V
result taking into account the measurement error to indicate the measurement of alternating current: 8A = 8 ± 0.067A
A table with the resolution and accuracy for a given measurement can be found in the user manual. BUILT-IN FUNCTIONS TRUE RMS - a meter with this function calculates the real effective value of alternating voltage and current for both sinusoidal and non-sinusoidal waveforms. The device first measures the actual value of the sine wave at several time intervals → then squares the measurement results → sums them → calculates the average → and finally squares the average result. The measurement result is the real effective value of alternating voltage/current, even for a deformed sine wave or square wave.
NCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in the insulated wire using the NCV sensor on the front of the device
AUTO - automatic adjustment of the measurement range. When measuring unknown values using a meter with a manual range change using a knob, measurements should be performed sequentially from the largest range to the range giving the most accurate result - otherwise you risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to perform one measurement and the meter will automatically find the optimal range. By default, the meter starts in AUTO mode
RANGE - manual change of the measurement range. A useful function when checking many of the same components with a known value, e.g. a series of resistors. Manually setting the range will significantly shorten the time of such measurements
REL - using the function during measurement will reset the display to zero and adopt the value visible before the display as the reference level. The next measurement will show the difference between the measured value and the stored reference value
MAX/MIN - keeping the maximum or minimum value from the current measurement on the display
HZ % - the button when setting the knob to the frequency measurement position will change the settings to measurement of duty cycle/duty factor
SELECT - changing the measurement mode, e.g. from AC to DC voltage measurement
DATA HOLD - keeping the currently measured value on the display ADDITIONAL INFORMATION LCD display, maximum displayed result: 19999
screen backlight
audible signal in the continuity test for resistance below 50Ω
ability to enable diode and circuit continuity tests separately
measuring probes 14.5 cm long
cable length with probes: 97 cm
wire diameter with insulation: 3.5 mm
immersion probe for temperature measurement
design with overload protection
ABS plastic housing
automatic shutdown of the meter after 15 minutes of inactivity
ability to disable the device's automatic shutdown mode
low battery indicator
power supply: two 1.5V(AA) batteries
Yato
Symbol
YT-730893
Series
GRE
Dimensions
180x90x45 mm
Material
ABS
Application
electrical
Operating temperature range
0~40 ˚C
Storage temperature
-10 ~ +50 ˚C
Power supply
battery
Battery type
2x1.5V; A.A
Mass
0.319 kg
Display type
LCD
Data Hold
Yes
Circuit continuity test
0-50 Ω
Conduction test
Yes
LED backlight
YES
Flashlight function
NO
Operating relative humidity Rh
<75%
Low battery indicator
Yes
Fuse
F200mAL250V / F20AL250V
AC voltage measurement
0-750 V a.c.
DC voltage measurement
0-999.9 V d.c.
Direct current
0-19.999A
Resistance measurement
0-199.99 MΩ
Diode test
YES
Alternating current
0-19.999A
Capacitance measurement
0-9.999 mF
Frequency measurement
0-9.999MHz
Temperature measurement
-20 ~ +1000 ˚C
Sampling frequency
3 times per second
TRUE RMS
Yes
Automatic measurement range
Yes
Maximum value
Yes
Fill factor measurement
1 ÷ 99%
Minimum value
Yes
Relative value
Yes
Sound signal
Yes
Display range
19999
Automatic shutdown
15 min
Non-contact NCV AC voltage detection
Yes YT-730893 universal meter with TRUE RMS function and automatic range for each measurement. It allows you to perform basic and advanced measurements of electrical quantities. A large multifunctional LCD display, a number of functions that facilitate measurements, speed of work and industrial precision will be appreciated by electronics, electricians and home DIY enthusiasts alike. The housing is equipped with a red rubber holster with dedicated places for measurement probes, thanks to which the meter does not easily slip out of your hands and minimizes the risk of damage during a fall. The test probe cables have silicone, flexible and high-temperature-resistant insulation. BASIC MEASUREMENTS AC voltage measurement: A.C. 0-750V, TRUE RMS
DC voltage measurement: D.C. 0-1000V
measurement of alternating current: A.C. 0-19.999A, TRUE RMS
measurement of direct current intensity: D.C. 0-19,999A
resistance measurement: 0-9,999MΩ
diode test: IF 1.8mA, UR 3.2V
circuit continuity test: 0-50Ω
ADDITIONAL MEASUREMENTS capacitor capacity measurement: 0-9,999mF
frequency measurement: 0-9,999Mhz
fill factor measurement: 1-99%
temperature measurement: -20 to 1000°C
non-contact detection of alternating voltage: NCV
MEASUREMENT ACCURACY An example of determining accuracy for measuring AC voltage. Calculations for the measurement result: 235V measurement accuracy of the YT-730893 meter for this range is: ±(0.3% + 3), resolution 0.1V
Measurement error calculation formula: (measurement result x 0.3%) + 3 x resolution
calculations: (235 x 0.3%) + 3 x 0.1 = 0.705 + 0.3 = 1.005V
The actual result taking into account the measurement error for the indication 235V = 235 ± 1.005V result taking into account the measurement error to indicate the DC voltage measurement: 12V = 12 ± 0.009V
result taking into account the measurement error to indicate the measurement of alternating current: 8A = 8 ± 0.067A
A table with the resolution and accuracy for a given measurement can be found in the user manual. BUILT-IN FUNCTIONS TRUE RMS - a meter with this function calculates the real effective value of alternating voltage and current for both sinusoidal and non-sinusoidal waveforms. The device first measures the actual value of the sine wave at several time intervals → then squares the measurement results → sums them → calculates the average → and finally squares the average result. The measurement result is the real effective value of alternating voltage/current, even for a deformed sine wave or square wave.
NCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in the insulated wire using the NCV sensor on the front of the device
AUTO - automatic adjustment of the measurement range. When measuring unknown values using a meter with a manual range change using a knob, measurements should be performed sequentially from the largest range to the range giving the most accurate result - otherwise you risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to perform one measurement and the meter will automatically find the optimal range. By default, the meter starts in AUTO mode
RANGE - manual change of the measurement range. A useful function when checking many of the same components with a known value, e.g. a series of resistors. Manually setting the range will significantly shorten the time of such measurements
REL - using the function during measurement will reset the display to zero and adopt the value visible before the display as the reference level. The next measurement will show the difference between the measured value and the stored reference value
MAX/MIN - keeping the maximum or minimum value from the current measurement on the display
HZ % - the button when setting the knob to the frequency measurement position will change the settings to measurement of duty cycle/duty factor
SELECT - changing the measurement mode, e.g. from AC to DC voltage measurement
DATA HOLD - keeping the currently measured value on the display ADDITIONAL INFORMATION LCD display, maximum displayed result: 19999
screen backlight
audible signal in the continuity test for resistance below 50Ω
ability to enable diode and circuit continuity tests separately
measuring probes 14.5 cm long
cable length with probes: 97 cm
wire diameter with insulation: 3.5 mm
immersion probe for temperature measurement
design with overload protection
ABS plastic housing
automatic shutdown of the meter after 15 minutes of inactivity
ability to disable the device's automatic shutdown mode
low battery indicator
power supply: two 1.5V(AA) batteries